Structural monitoring — solutions by industry
A bridge behaves differently than a high-rise, and a dam differently than the roof of a warehouse. For 15 years the Inclify team has been installing measurement systems on structures where there is no room for error — from stadiums to navigation locks. Pick your industry and see what we measure, and how.
The structures we monitor
The same platform, different sensors, different thresholds — matched to the physics of the particular structure.
Bridges and viaducts
Span deflections, bearing and expansion joint movement, pier tilt, traffic-induced vibration — during service and during reconstruction.
Bridge monitoring →Buildings
Settlement and tilt of buildings next to adjacent construction works, crack opening, snow load on large-span warehouse roofs.
Building monitoring →Power generation
Cooling towers, industrial chimneys, masts and towers, turbine foundations — data for planning repairs within maintenance windows.
Monitoring in the power sector →Mining and tunnels
Deformation of tunnel and excavation linings, plus the effect of mining on the ground surface and structures within the zone of influence.
Monitoring in mining →Dams and weirs
Pore pressures in the body and the foundation, displacements and expansion joint movement — retaining structures under constant supervision.
Dam monitoring →Inclinometry
Tilt and displacement measurement: slopes, diaphragm walls, deep excavations, embankments — anywhere the ground is on the move.
Inclinometry →One approach, different structures
Whatever the industry, the path is the same: from the site audit to an alert on the phone of the person who has to react.
We review the structure, the documentation and the real risks. We establish which physical quantities actually say something about the safety of the structure.
From over 40 sensor types we pick the right ones: vibrating wire sensors with 20+ years of stability where the horizon is measured in decades, accelerometers where vibration is the issue.
Readings every 15 minutes by default, or more often, calculation equations, baseline reading, CSV/XLSX exports. We also integrate existing data loggers over REST, CSV or FTP.
Warning and alarm thresholds plus no-data supervision. An exceedance triggers an immediate SMS, e-mail or push notification — with the full history in the audit trail.
Don't see your industry? Write to us
Describe the structure and the problem, and we will propose a measurement scope, sensor selection and a quote. Plans start at PLN 9,500 net per year.